Condition Monitoring System and Automatic Air Cleaning in the Toilet of Firebase-Based Andalas University Lecture Building

Main Article Content

Randa Multri Okta Ilham
Rizka Hadelina
Mohammad Hafiz Hersyah
Lathifah Arief

Abstract

Maintaining the cleanliness and comfort of toilets in lecture buildings is very important for the quality of the campus environment. This study develops a Firebase-based Automatic Air Condition Monitoring and Cleaning System in the restrooms of Andalas University lecture halls. The main problem identified is the lack of direct monitoring, which leads to the appearance of unpleasant odors and potential health problems. A survey showed that 64.8% of respondents sometimes felt unpleasant odors, while 59.3% indicated a lack of adequate air circulation.To solve this problem, the designed system is able to detect and monitor toilet conditions in real-time through gas measurements such as ammonia, hydrogen sulfide, and carbon monoxide using MQ-135, MQ-136, and MQ-7 sensors, the results of which can be monitored through a website.  The system not only monitors, but also controls air quality by turning on the exhaust fan when the gas level exceeds a certain. Tests show that the system is accurate in detecting gas, with sensor precision above 90% and an average data transmission time of 1.74 seconds. However, the humidity measurement showed an error rate of 32.36%. The system effectively improves the hygiene monitoring of restrooms, thereby improving comfort and health on campus

Article Details

How to Cite
[1]
R. Multri Okta Ilham, R. Hadelina, M. H. Hersyah, and L. Arief, “Condition Monitoring System and Automatic Air Cleaning in the Toilet of Firebase-Based Andalas University Lecture Building”, chipset, vol. 6, no. 02, pp. 117-123, Oct. 2025.
Section
Articles

References

[1] M. Alfarisi, F. Yudi Limpraptono, T. Elektro, and I. Teknologi Nasional Malang Jl Raya Karanglo Km, “SENIATI 2022: Design and Development of an IoT-Based Automatic Air Monitoring and Cleaning System for Public Toilets,” no. 2, p. 3.

[2] H. A. Hermadi and S. H. Warsito, “Eliminating Open Defecation in Surabaya by Providing Odor-Free and Overflow-Proof Toilets in Jagir Wonokromo Village,” Journal of Public Services (J. Layanan Masy), vol. 4, no. 1, pp. 53–53, 2020, doi: 10.20473/jlm.v4i1.2020.53-61.

[3] F. Abdullah, Mb. Diaz Pranita, P. Jasa Tirta, and P. Masyarakat dan Peningkatan Kualitas Sumber Daya Manusia, “Guidelines for Clean Toilets and Community-Based Sanitation in Toba Tourism Villages.”

[4] Bradburn, Steven. "How To Calculate The Coefficient Of Variation," YouTube, Aug. 13, 2019 [Video file]. Available: https://www.youtube.com/watch?v=OI1wzkuKS6Y. [Accessed: Aug. 13, 2024].

[5] Ministry of Health, “Minister of Health Regulation Number 2 of 2023 on Implementation Regulations of Government Regulation Number 66 of 2014 concerning Environmental Health.” Accessed: Dec. 25, 2023. [Online]. Available: https://peraturan.bpk.go.id/Details/245563/permenkes-no-2-tahun-2023.

[6] N. Bugrov et al., “Fecal Microbiota Analysis in Cats with Intestinal Dysbiosis of Varying Severity,” Pathogens, vol. 11, no. 2, Feb. 2022, doi: 10.3390/pathogens11020234.

[7] P. Pahare and P. Jain, “Study of Reliability of Electrochemical Sensors MQ-135 and MQ-137 for Detecting Ammonia Gas in Male Urinals Implemented on an IoT-Based System,” International Journal for Research in Engineering Application & Management (IJREAM), vol. 05, pp. 2454–9150, 2019, doi: 10.35291/2454-9150.2019.0340.

[8] F. Abdullah, Mb. Diaz Pranita, P. Jasa Tirta, and P. Masyarakat dan Peningkatan Kualitas Sumber Daya Manusia, “Guidelines for Clean Toilets and Community-Based Sanitation in Toba Tourism Villages.”

[9] Ministry of Culture and Tourism, “Indonesian Public Toilet Standards,” Library of the Ministry of Public Works and Public Housing.

[10] D. Wahyu Saputra, R. Maulana, and G. Edhi Setyawan, “Toilet Condition Quality Classification System Based on Gas and Temperature Using MQ135 and DHT11 Sensors with Naive Bayes Method,” 2019. [Online]. Available: https://j-ptiik.ub.ac.id

[11] S. Aji, “Ammonia Threshold Levels Hazardous to Workers,” Independent Journal Alliance, 2013. Accessed: Dec. 25, 2023. [Online]. Available: https://www.ajisurabaya.org/2013/03/28/hasil-disertasi-abdul-rohim-tualeka/

[12] ditppu.menlhk.go.id, “Air Pollutant Standard Index (ISPU) as Ambient Air Quality Information in Indonesia.” Accessed: Jan. 16, 2024. [Online]. Available: https://ditppu.menlhk.go.id/portal/read/indeks-standar-pencemar-udara-ispu-sebagai-informasi-mutu-udara-ambien-di-indonesia